Power station glossary
The terms you'll meet on spec sheets, in one place.
- Watt (W)
- The rate at which an appliance uses power right now. It decides whether a station can run something at all. More →
- Watt-hour (Wh)
- Energy over time: 100 W for 1 hour is 100 Wh. A station’s capacity is in Wh, and it decides how long things run. 1 kWh = 1,000 Wh. More →
- Continuous output
- The most power the inverter can supply indefinitely. Everything you run at the same time must fit under it.
- Surge (peak) power
- A brief overload the inverter tolerates for a fraction of a second, used to start motors and compressors. More →
- Duty cycle
- The share of time an appliance actually draws power. A fridge compressor runs about 30–40% of the time, so its daily energy is far below watts × 24.
- Inverter
- Converts the battery’s DC power to household AC. It wastes roughly 10–15% as heat and draws a little power just being on.
- Pure sine wave
- AC output that matches grid power. All mainstream power stations provide it; it matters for motors, medical devices and sensitive electronics.
- LFP (LiFePO₄)
- Lithium iron phosphate battery chemistry. Heavier than NMC but rated for thousands of cycles and more thermally stable. More →
- NMC
- Nickel manganese cobalt lithium chemistry. Lighter, but typically rated for 500–1,000 cycles. More →
- Cycle life
- How many full charge-discharge cycles a battery is rated for before it falls to about 80% of original capacity. More →
- BMS
- Battery management system: electronics that protect the cells from overcharge, deep discharge, overheating and charging in the cold.
- Usable capacity
- The share of rated Wh you can actually draw. We assume 95% before inverter losses. More →
- Peak sun hours
- The number of hours of full-strength (1,000 W/m²) sunlight a day delivers in total. About 4 across the US on average; 2–3 in winter. More →
- MPPT
- Maximum power point tracking: the solar charge controller inside a station that pulls the most power from panels as light changes.
- Solar input limit
- The most panel wattage (and voltage) a station accepts. Extra panel watts beyond it are wasted.
- Voc (open-circuit voltage)
- A panel’s voltage with nothing connected. Panels in series add their Voc, which must stay under the station’s input voltage limit.
- Solar generator
- Marketing name for a power station bundled with solar panels. No fuel is involved. More →
- Pass-through charging
- Running devices from the station while it charges. More →
- UPS / EPS
- A mode where the station switches its outlets to battery when grid power fails. The switchover takes about 10–30 ms on power stations. More →
- Expansion battery
- A brand-specific add-on battery that plugs into a station to multiply its capacity.
- Transfer switch
- An electrician-installed switch that safely connects a station or generator to selected home circuits while isolating the grid. More →
- Backfeeding
- Feeding power into a home through an outlet with a "suicide cord". Illegal and deadly to line workers; never do it. More →
- 240 V / split phase
- The higher US household voltage used by well pumps, dryers and ranges. Only large home-backup stations (or two linked units) supply it.
- Anderson / XT60
- Common DC connectors for solar input and high-current 12 V output.