How we calculate

The calculator is deliberately simple and transparent. Here is every number it uses, and why.

1. Daily energy

For each appliance: watts × duty cycle × hours per day × quantity ÷ efficiency.

  • Watts default to a typical model (editable). Each runtime page lists the usual range.
  • Duty cycle is the share of "on" time an appliance actually draws power. Compressors cycle: we use 40% for refrigerators, 35% for freezers and 12 V fridges, 60% for air conditioners, 15% for a sump pump in heavy rain. Electronics and heaters on full are 100%.
  • Efficiency is 85% for anything on the AC outlets (inverter conversion and idle draw) and 92% for 12 V and USB outlets, which skip the inverter. Manufacturers quote 85–90% inverter efficiency at moderate loads; light loads are less efficient, so we use the lower end.

2. Usable capacity

We count 95% of a station's rated watt-hours as usable. Battery management systems keep a small reserve, and capacity declines slowly with use. Near or below freezing, lithium cells deliver less, so the "cold" option multiplies capacity by 0.8.

The capacity we recommend is daily energy × days × (1 + safety margin) ÷ (0.95 × cold factor). The default margin is 20%.

3. Output and surge

Continuous load is everything that runs for long stretches (fridges, CPAPs, lights, routers) plus the single largest "burst" appliance (microwave, kettle, hair dryer) — we assume you won't run two bursts at once. That total must fit under the station's continuous AC output.

Start-up surge is that continuous load plus the largest single motor spike (start-up watts minus running watts). If a station doesn't publish a surge rating, we assume it has none beyond its continuous output, which is conservative.

Appliances marked as 240 V (most well pumps) can only run on stations with native 240 V output or paired units.

4. Solar

Panels deliver about 70% of their rating in real use (heat, angle, dust, controller losses). Daily solar energy is min(your panel watts, station's solar input limit) × peak sun hours × 0.7. The default is 4 peak sun hours, a fair average across US seasons and latitudes. If solar covers your daily use, we mark the station as able to run indefinitely in good sun.

5. Ranking

  1. Stations that meet output, surge, voltage and capacity needs come first; then stations that meet them with the brand's add-on battery; then those that fall short (closest first).
  2. Among stations that fit, the smallest adequate capacity wins — buying far more battery than you need is the most common mistake.
  3. Ties (within 150 Wh) go to the lower price band, then the lighter unit.

Guides use the same engine on a fixed scenario and may sort by weight (camping, CPAP) or price band (single-appliance guides). Affiliate commissions play no part in any ranking.

6. Specs

Specs come from manufacturers' published listings and were last checked 2026-11. Where a figure isn't published or we couldn't confirm it, we show "—" rather than guess. Price bands reflect typical street prices and change often; always check the current price.

Limits

  • Real appliances vary widely. A plug-in energy meter over 24 hours beats any estimate.
  • Runtime estimates assume room temperature and a healthy battery.
  • Anything hard-wired (furnaces, well pumps, ceiling fans) needs a transfer switch or inlet installed by a licensed electrician.
  • Medical devices: a power station is not a substitute for a medical backup plan. Ask your provider.